Deye Solar R290 Air to Water Heat Pump | 10/12/16kW Hybrid ACDC

From 17.618,00 lei

Skip to product information
Model

Regular price 17.618,00 lei
Sale price 17.618,00 lei Regular price
Tax included.
Low stock! Only 10 left

R290 Hybrid ACDC monoblock for heating, cooling and DHW. A+++ at 35 °C LWT, GWP 3 refrigerant, full DC inverter, Wi-Fi and Deye Cloud. Direct PV when you have it, grid AC when you do not.

Key specifications

Series

Deye R290 Heat Pump Monoblock · Hybrid ACDC

This listing

10 kW 1Ph · 12 kW 1Ph · 12 kW 3Ph · 16 kW 3Ph

Refrigerant

R290 · GWP 3

Heating A7/W35

10.0 / 12.0 / 12.0 / 16.0 kW · COP 4.70 / 4.80 / 4.80 / 4.40

Seasonal class

A+++ at 35 °C LWT (average climate, EN 14825)

DHW / heating water

DHW set 25–75 °C · heating set 25–80 °C · sterilisation 65 °C

Ambient

Heating −25 to +35 °C · cooling −5 to +48 °C · DHW −25 to +43 °C

Cabinet

1283 × 455 × 1036 mm · G1-1/4″ · Wi-Fi / Modbus / SG Ready

Heating, cooling and DHW

One outdoor monoblock for space heating, comfort cooling and domestic hot water. Typical hydraulics: underfloor, radiators, fan coils, buffer tank and DHW tank.

Heating A7/W35: 10.0 / 12.0 / 12.0 / 16.0 kW for the four listed SKUs. Cooling A35/W18: 10.0 / 12.0 / 12.0 / 16.0 kW. Backup heater 3 kW (1Ph) or 9 kW (3Ph). Max input does not include the backup heater.

Hybrid ACDC and Deye Cloud

Hybrid ACDC: use compatible PV on the built-in MPPT when the sun is available, and AC grid power when it is not. Pair with a Deye inverter, battery and Cloud app for scheduling across PV, storage, heat pump and household loads.

Wi-Fi, Modbus, SG Ready, zone control, ECO / holiday modes, OTA and leakage control. Up to 8 units can be modularised. CE, ERP, MCS and BAFA list marks.

Install, size and compliance

Sound power 57 / 57 / 57 / 58 dB(A). Net weight 150 / 167 / 186 / 186 kg. Packing 1360 × 545 × 1222 mm. Expansion vessel 5 L, safety valve 0.3 MPa, flow switch 0.36 / 0.6 / 0.6 / 0.6 m³/h. R290 charge 1.1 / 1.43 / 1.43 / 1.43 kg.

Price is for the equipment only. Installation must be done by a qualified heat-pump installer. Confirm capacity, PV strings, AC supply, hydraulics and local subsidy rules before order. Test standard EN 14825. Relevant: EN14511, EN14825, EN50564, EN12102, (EU) 811/2013, 813/2013, 207/2012, 2014.

Deye Solar R290 Air to Water Heat Pump | 10/12/16kW Hybrid ACDC

17.618,00 lei

  • Seasonal class

    A+++

    LWT 35 °C, average climate

  • Refrigerant

    R290

    GWP 3 · ECO

  • Heating water

    80°C

    setpoint · DHW to 75 °C

  • Ambient heat

    -25°C

    heating down to −25 °C

R290 Hybrid ACDC monoblock

Heat, cool and make hot water. Solar when you have it.

Deye R290 Heat Pump Monoblock (stock 605117) for a zero-carbon home stack: PV, inverter, battery, heat pump, DHW and emitters — scheduled in Deye Cloud.

Why this heat pump

This store page sells the 10/12 kW 1Ph and 12/16 kW 3Ph Hybrid ACDC SKUs.

  • R290 and A
    + seasonal class

    Natural refrigerant GWP 3. Seasonal class A+++ at 35 °C LWT (A++ at 55 °C on the 16 kW 3Ph). Full DC inverter and ECO / auto water-temp modes.

  • Hybrid ACDC

    Feed compatible PV into the MPPT for daytime heating, cooling and DHW. Keep running from 220–240 V 1Ph or 380–415 V 3Ph AC when the roof is quiet.

  • One outdoor unit, three jobs

    Space heating, comfort cooling and DHW. Floor loops, radiators, fan coils, buffer and DHW tank through G1-1/4″ connections and 3-way valves.

  • Deye Cloud and SG Ready

    Wi-Fi, Modbus, zone control, OTA, holiday mode, 65 °C sterilisation, leakage control. Schedule the heat pump with PV, battery and EV charging in the Cloud app.

Specifications

Technical data

Models DAWG1-ACDC-10R3EP / -12R3EP / ACDC2-12R3EP / ACDC2-16R3EP
Power supply 220–240 V 1Ph 50/60 Hz · 380–415 V 3Ph 50/60 Hz
Cooling A35/W18 capacity 10.0 / 12.0 / 12.0 / 16.0 kW
Cooling A35/W18 input / EER 2.11 / 2.47 / 2.47 / 4.10 kW · EER 4.75 / 4.50 / 4.50 / 3.90
Cooling A35/W7 capacity 8.9 / 11.5 / 11.5 / 14.0 kW
Heating A7/W35 capacity / COP 10.0 / 12.0 / 12.0 / 16.0 kW · COP 4.70 / 4.80 / 4.80 / 4.40
Heating A7/W45 capacity / COP 10.0 / 12.0 / 12.0 / 16.0 kW · COP 3.65 / 3.70 / 3.70 / 3.35
Heating A7/W55 capacity / COP 9.5 / 12.0 / 12.0 / 16.0 kW · COP 3.05 / 3.10 / 3.10 / 2.85
Seasonal class LWT 35 / 55 °C A+++ / A+++ / A+++ / A+++ · A+++ / A+++ / A+++ / A++
ErP sound power 57 / 57 / 57 / 58 dB(A)
Net / packing size 1283 × 455 × 1036 mm · 1360 × 545 × 1222 mm
Net / gross weight 150 / 167 / 186 / 186 kg · 174 / 191 / 210 / 210 kg
Max power input (excl. backup) 3.4 / 4.8 / 4.8 / 5.9 kW
Backup heater 3 / 3 / 9 / 9 kW
R290 charge 1.1 / 1.43 / 1.43 / 1.43 kg
Flow switch / expansion vessel 0.36 / 0.6 / 0.6 / 0.6 m³/h · 5 L · 0.3 MPa
Piping G1-1/4 inch
Features Wi-Fi · Modbus · SG Ready · zone control · OTA · modular 8 units · leakage control

Which models are on this page?

Four Hybrid ACDC SKUs: DAWG1-ACDC-10R3EP (10 kW 1Ph), DAWG1-ACDC-12R3EP (12 kW 1Ph), DAWG1-ACDC2-12R3EP (12 kW 3Ph) and DAWG1-ACDC2-16R3EP (16 kW 3Ph). 8 kW 1Ph and 16 kW 1Ph are not sold on this page.

Can it run without solar panels?

Yes. Compatible PV can support the unit through the Hybrid ACDC MPPT, but it also runs from grid AC when PV is missing, offline or too weak — evenings, cloud and high demand included.

What can it heat or cool?

Space heating, comfort cooling and domestic hot water. Typical plant: underfloor, radiators, fan coils, buffer tank and DHW tank. It is not the Deye R32 swimming-pool heat pump.

How do I choose 10, 12 or 16 kW?

Size from heat loss, insulation, DHW volume, emitters, climate, AC supply and PV. Many houses take 10 or 12 kW 1Ph; higher load or a 3Ph supply takes 12 or 16 kW 3Ph. A qualified installer must confirm.

Does it replace a gas or oil boiler?

It can be designed as a boiler replacement or a new-build low-carbon plant, but the result depends on the building, emitters, DHW cylinder and local rules. Installation is not in the equipment price.

Who should install it?

A qualified heat-pump installer: hydraulics, electrical supply, PV strings, outdoor placement, drainage and subsidy paperwork. In the box: outdoor unit, wired controller, manuals.

Ready for an R290 Hybrid ACDC home

A+++ at 35 °C LWT, heating to 80 °C water, Deye Cloud, SG Ready.

A+++ · 35 °C
R290 · GWP 3
Hybrid ACDC
Wi-Fi · Cloud