Deye SUN-5/6/8/10/12K-SG02HP3-EU-DM2 | 5–12kW Three-Phase HV Hybrid Inverter

From 300.100 Ft

Skip to product information
1 of 5
Capacity

Regular price 300.100 Ft
Sale price 300.100 Ft Regular price
Tax included.

Three-phase high-voltage hybrid inverter for PV plus storage. 5–12kW, 2 MPPTs, battery 130–700V, up to 10 units in parallel, 100% unbalanced output.

Key specifications

Series

SUN-5/6/8/10/12K-SG02HP3-EU-DM2

Rated power

5 / 6 / 8 / 10 / 12kW three-phase

Max. efficiency

97.6% (Euro 97.0%, MPPT >99%)

Battery

Lithium-ion, 130–700V, 37A or 55A, 1 input

MPPT

2 trackers, 1 string each (1+1)

Parallel

Up to 10 units on-grid and off-grid

Ingress protection

IP65

Warranty

5 years, up to 10 years by country

Battery and backup

High-voltage lithium battery 130–700V. Charge/discharge 37A on 5kW and 6kW, 55A on 8kW, 10kW and 12kW. One battery input, BMS self-adaptation, six charge/discharge windows. Off-grid peak 1.5× rated for 10s. Diesel generator energy can be stored in the battery. Multiple batteries in parallel.

PV and grid

Max. PV voltage 1000V, MPPT 150–850V, start-up 130V, rated 600V. Two MPPTs, one string each (1+1), 20A+20A operating, 30A+30A ISC. Rated AC 220/380V or 230/400V, 3L+N+PE, 50/60Hz. 100% unbalanced output. AC couple to an existing PV plant. Grid-to-load passthrough 35A continuous.

Protection and monitoring

Integrated DC reverse polarity, AC overcurrent/overvoltage/short-circuit, thermal, anti-islanding, insulation monitoring, residual current detection, DC switch, DC component monitoring, Type II surge on DC and AC. Optional AFCI. RS485, RS232, CAN. GPRS/WiFi/Bluetooth/4G/LAN optional. −40°C to +60°C, derating above 45°C. Humidity 0–100%. Altitude 2000m. Noise ≤45dB.

Deye SUN-5/6/8/10/12K-SG02HP3-EU-DM2 | 5–12kW Three-Phase HV Hybrid Inverter

300.100 Ft

  • Battery

    130-700V
  • MPPTs

    2
  • Max. efficiency

    97.6%
  • Parallel

    10

High-voltage storage

130–700 V battery, 97.6% max. efficiency

The lithium-ion battery input is 130–700 V, with one battery input and charging that self-adapts to the BMS.

Max. efficiency is 97.6%. Euro efficiency is 97.0%.

Max. charge and discharge current is 37 A on the 5 kW and 6 kW models, and 55 A on the 8 kW, 10 kW and 12 kW models.

  • 130–700 V battery voltage
  • 97.6% max. efficiency
  • 37 A / 55 A charge current
  • 1 battery input

Dual MPPT

Two trackers, 20 A + 20 A

Two MPP trackers take one string each (2/1+1).

Max. operating PV input current is 20 A + 20 A. Max. input short-circuit current is 30 A + 30 A.

The MPPT window is 150–850 V. Max. PV input voltage is 1000 V, start-up is 130 V, and rated PV input voltage is 600 V. MPPT efficiency is >99%.

  • 2 MPPTs
  • 20+20 A PV input current
  • 150–850 V MPPT range
  • >99% MPPT efficiency

Three-phase output

100% unbalanced output

Output can be 100% unbalanced across the three phases.

Rated input and output voltage is 220/380 V and 230/400 V, 0.85Un–1.1Un, 3L+N+PE.

Rated AC active power is 5000 W, 6000 W, 8000 W, 10000 W and 12000 W by model. Grid frequency is 50 Hz (45–55 Hz) or 60 Hz (55–65 Hz).

  • 100% unbalanced output
  • 3L+N+PE connection
  • 220/380 V rated voltage
  • 50/60 Hz grid frequency

Parallel

Up to 10 units, on-grid or off-grid

Up to 10 inverters can run in parallel for on-grid and off-grid operation.

Multiple batteries can be connected in parallel as well.

  • 10 inverters in parallel
  • On-grid parallel operation
  • Off-grid parallel operation

Existing PV

AC couple an existing solar system

AC coupling retrofits this hybrid inverter onto an existing solar system.

The existing PV stays in place, and this inverter adds battery storage.

  • AC couple retrofit existing PV

Scheduling

Six charge and discharge periods

Battery charging and discharging can be set across 6 time periods.

Each period is a charge or discharge window for the battery.

  • 6 time periods

Generator

Store energy from a diesel generator

The inverter can store energy from a diesel generator in the battery.

That stored energy is available for later use.

  • Diesel generator energy stored

Outdoor and monitoring

IP65, with open communication

Ingress protection is IP65.

Communication interfaces are RS485, RS232 and CAN. The display is LCD and LED.

Monitoring is optional: GPRS, Wi-Fi, Bluetooth, 4G or LAN.

  • IP65 ingress protection
  • RS485 RS232, CAN
  • LCD+LED display
  • Optional GPRS / Wi-Fi / 4G / LAN
SPECIFICATIONS

Technical data

Parameter SUN-5K-SG02HP3-EU-DM2 SUN-6K-SG02HP3-EU-DM2 SUN-8K-SG02HP3-EU-DM2 SUN-10K-SG02HP3-EU-DM2 SUN-12K-SG02HP3-EU-DM2
Rated AC active power 5000 W 6000 W 8000 W 10000 W 12000 W
Max. AC apparent power 5500 VA 6600 VA 8800 VA 11000 VA 13200 VA
Rated AC current 7.6/7.3 A 9.1/8.7 A 12.2/11.6 A 15.2/14.5 A 18.2/17.4 A
Max. AC current 8.4/8.0 A 10/9.6 A 13.4/12.8 A 16.7/16 A 20/19.2 A
Max. continuous AC passthrough 35 A 35 A 35 A 35 A 35 A
Peak power (off-grid) 1.5× rated, 10 s 1.5× rated, 10 s 1.5× rated, 10 s 1.5× rated, 10 s 1.5× rated, 10 s
Power factor 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging
THDi <3% <3% <3% <3% <3%
DC injection current <0.5% In <0.5% In <0.5% In <0.5% In <0.5% In
Rated voltage 220/380 V, 230/400 V 220/380 V, 230/400 V 220/380 V, 230/400 V 220/380 V, 230/400 V 220/380 V, 230/400 V
Voltage range / phases 0.85Un–1.1Un, 3L+N+PE 0.85Un–1.1Un, 3L+N+PE 0.85Un–1.1Un, 3L+N+PE 0.85Un–1.1Un, 3L+N+PE 0.85Un–1.1Un, 3L+N+PE
Grid frequency 50/45–55, 60/55–65 Hz 50/45–55, 60/55–65 Hz 50/45–55, 60/55–65 Hz 50/45–55, 60/55–65 Hz 50/45–55, 60/55–65 Hz
Unbalanced output 100% 100% 100% 100% 100%
Battery type Lithium-ion Lithium-ion Lithium-ion Lithium-ion Lithium-ion
Battery voltage 130–700 V 130–700 V 130–700 V 130–700 V 130–700 V
Max. charge/discharge current 37 A 37 A 55 A 55 A 55 A
Li-ion charging strategy Self-adaption to BMS Self-adaption to BMS Self-adaption to BMS Self-adaption to BMS Self-adaption to BMS
Battery inputs 1 1 1 1 1
Max. PV access power 10000 W 12000 W 16000 W 20000 W 24000 W
Max. PV input power 8000 W 9600 W 12800 W 16000 W 19200 W
Max. PV input voltage 1000 V 1000 V 1000 V 1000 V 1000 V
Start-up voltage 130 V 130 V 130 V 130 V 130 V
MPPT voltage range 150–850 V 150–850 V 150–850 V 150–850 V 150–850 V
Rated PV input voltage 600 V 600 V 600 V 600 V 600 V
Max. operating PV input current 20+20 A 20+20 A 20+20 A 20+20 A 20+20 A
Max. input short-circuit current 30+30 A 30+30 A 30+30 A 30+30 A 30+30 A
MPP trackers / strings 2/1+1 2/1+1 2/1+1 2/1+1 2/1+1
Max. efficiency 97.6% 97.6% 97.6% 97.6% 97.6%
Euro efficiency 97.0% 97.0% 97.0% 97.0% 97.0%
MPPT efficiency >99% >99% >99% >99% >99%
Parallel Max. 10, on-grid and off-grid Max. 10, on-grid and off-grid Max. 10, on-grid and off-grid Max. 10, on-grid and off-grid Max. 10, on-grid and off-grid
Charge/discharge periods 6 6 6 6 6
AC coupling Retrofit existing solar system Retrofit existing solar system Retrofit existing solar system Retrofit existing solar system Retrofit existing solar system
Diesel generator Store generator energy Store generator energy Store generator energy Store generator energy Store generator energy
Ingress protection IP65 IP65 IP65 IP65 IP65
Surge protection Type II (DC), Type II (AC) Type II (DC), Type II (AC) Type II (DC), Type II (AC) Type II (DC), Type II (AC) Type II (DC), Type II (AC)
Cooling Natural cooling Natural cooling Intelligent air cooling Intelligent air cooling Intelligent air cooling
Operating temperature −40 to +60°C, derating above 45°C −40 to +60°C, derating above 45°C −40 to +60°C, derating above 45°C −40 to +60°C, derating above 45°C −40 to +60°C, derating above 45°C
Ambient humidity 0–100% 0–100% 0–100% 0–100% 0–100%
Altitude 2000 m 2000 m 2000 m 2000 m 2000 m
Noise ≤45 dB ≤45 dB ≤45 dB ≤45 dB ≤45 dB
Topology Non-isolated Non-isolated Non-isolated Non-isolated Non-isolated
Overvoltage category OVC II (DC), OVC III (AC) OVC II (DC), OVC III (AC) OVC II (DC), OVC III (AC) OVC II (DC), OVC III (AC) OVC II (DC), OVC III (AC)
Display LCD+LED LCD+LED LCD+LED LCD+LED LCD+LED
Communication RS485, RS232, CAN RS485, RS232, CAN RS485, RS232, CAN RS485, RS232, CAN RS485, RS232, CAN
Monitor mode GPRS/Wi-Fi/Bluetooth/4G/LAN, optional GPRS/Wi-Fi/Bluetooth/4G/LAN, optional GPRS/Wi-Fi/Bluetooth/4G/LAN, optional GPRS/Wi-Fi/Bluetooth/4G/LAN, optional GPRS/Wi-Fi/Bluetooth/4G/LAN, optional
Warranty 5 years / up to 10 years 5 years / up to 10 years 5 years / up to 10 years 5 years / up to 10 years 5 years / up to 10 years

Which models are in this series?

Five SKUs: SUN-5K, 6K, 8K, 10K and 12K-SG02HP3-EU-DM2. All have 2 MPPTs (1+1), 130–700V battery, three-phase AC. Battery current is 37A on 5kW/6kW and 55A on 8kW/10kW/12kW.

Can I add storage to an existing PV plant?

Yes. AC coupling lets you retrofit this hybrid inverter onto an existing solar system without replacing the original grid-tied inverter.

Does it support a diesel generator?

Yes. The inverter can store generator energy in the battery for weak-grid, off-grid and backup sites.

How does cooling differ by model?

5kW and 6kW use natural cooling. 8kW, 10kW and 12kW use intelligent air cooling. Noise is ≤45dB.

What warranty is included?

5 years, up to 10 years depending on installation country. Refer to the Deye warranty policy for the site country.