Deye SUN-75/80K-SG02HP3-EU-EM6 | 75–80kW Three-Phase HV Hybrid Inverter
€4.547,95
-
Battery
160-1000V -
MPPTs
6 -
Max. efficiency
98.7% -
Parallel
10

Conversion
98.7% on a 75–80 kW plant.
Max. efficiency is 98.7%. Euro efficiency is 98.1%, and MPPT efficiency stays above 99%. On a factory or warehouse roof, that is how much of the array remains available on the AC side.
- 98.7% max. efficiency
- 98.1% Euro efficiency
- >99% MPPT efficiency

PV layout
Six roofs, one inverter.
Six MPPTs, with strings arranged 2+2+2+2+2+2, and 36 A on each tracker. A warehouse, a carport, and an east-west field can each hold their own voltage. Max. PV input is 1000 V, and the MPPT window is 150–850 V.
- 6 MPPTs
- 12 strings
- 36 A per tracker

Storage
Two battery inputs, one hybrid.
Lithium batteries from 160 V to 1000 V connect on two inputs at 80 A each. Charging follows the BMS. Use both inputs to move daytime solar into the afternoon peak on a 75 kW or 80 kW site.
- 160–1000 V battery
- 80+80 A charge / discharge
- 2 battery inputs

Time of use
Six windows in the working day.
Charging and discharging can be set across six periods. Fill the battery when the site tariff is low, and discharge when the process load is high. The clock times are set on site.
- 6 time periods
- Charge low-tariff hours
- Discharge process load

Expansion
Grow past a single cabinet.
Up to 10 inverters can run in parallel for on-grid and off-grid operation. Batteries can be paralleled as well. Start with one 75 kW or 80 kW unit and add cabinets as the load grows.
- 10 inverters
- On-grid and off-grid
- Batteries in parallel

Retrofit
Leave the existing array in place.
AC coupling adds this hybrid inverter to a solar system that is already running. The original PV stays in service. The new unit brings battery storage for peak shaving or backup.
- AC couple retrofit
- Existing PV stays
- Battery added

Backup
The generator fills the battery.
Energy from a diesel generator can be stored in the battery when the grid is down. Off-grid peak power is 1.5 times rated power for 10 seconds, enough for a motor start while the generator covers the longer outage.
- Diesel into the battery
- 1.5× rated, off-grid
- 10 s peak

Outdoor plant
Mount it on the plant wall.
Ingress protection is IP65, so the cabinet can sit outdoors beside a switch room. Communication is RS485, RS232, and CAN, with an LCD and LED display. Monitoring can use GPRS, Wi-Fi, Bluetooth, 4G, or LAN.
- IP65 ingress protection
- RS485, RS232, CAN communication
- LCD + LED display
Technical data
| Parameter | SUN-75K-SG02HP3-EU-EM6 | SUN-80K-SG02HP3-EU-EM6 |
|---|---|---|
| Rated AC active power | 75000 W | 80000 W |
| Max. AC apparent power | 82500 VA | 88000 VA |
| Battery voltage | 160–1000 V | 160–1000 V |
| Max. charge/discharge current | 80+80 A | 80+80 A |
| MPP trackers / strings | 6/2+2+2+2+2+2 | 6/2+2+2+2+2+2 |
| MPPT voltage range | 150–850 V | 150–850 V |
| Max. PV input voltage | 1000 V | 1000 V |
| Max. operating current per MPPT | 36 A | 36 A |
| Max. efficiency | 98.7% | 98.7% |
| Parallel | Max. 10, on-grid and off-grid | Max. 10, on-grid and off-grid |
| Ingress protection | IP65 | IP65 |
| Cabinet size (W×H×D) | 606×927×314 mm | 606×927×314 mm |
| Weight | 105 kg | 105 kg |