Deye SUN-5/6/8/10/12K-SG02HP3-EU-DM2 | 5–12kW Three-Phase HV Hybrid Inverter
From €823,95
-
Battery
130-700V -
MPPTs
2 -
Max. efficiency
97.6% -
Parallel
10

High-voltage storage
130–700 V battery, 97.6% max. efficiency
The lithium-ion battery input is 130–700 V, with one battery input and charging that self-adapts to the BMS.
Max. efficiency is 97.6%. Euro efficiency is 97.0%.
Max. charge and discharge current is 37 A on the 5 kW and 6 kW models, and 55 A on the 8 kW, 10 kW and 12 kW models.
- 130–700 V battery voltage
- 97.6% max. efficiency
- 37 A / 55 A charge current
- 1 battery input

Dual MPPT
Two trackers, 20 A + 20 A
Two MPP trackers take one string each (2/1+1).
Max. operating PV input current is 20 A + 20 A. Max. input short-circuit current is 30 A + 30 A.
The MPPT window is 150–850 V. Max. PV input voltage is 1000 V, start-up is 130 V, and rated PV input voltage is 600 V. MPPT efficiency is >99%.
- 2 MPPTs
- 20+20 A PV input current
- 150–850 V MPPT range
- >99% MPPT efficiency

Three-phase output
100% unbalanced output
Output can be 100% unbalanced across the three phases.
Rated input and output voltage is 220/380 V and 230/400 V, 0.85Un–1.1Un, 3L+N+PE.
Rated AC active power is 5000 W, 6000 W, 8000 W, 10000 W and 12000 W by model. Grid frequency is 50 Hz (45–55 Hz) or 60 Hz (55–65 Hz).
- 100% unbalanced output
- 3L+N+PE connection
- 220/380 V rated voltage
- 50/60 Hz grid frequency

Parallel
Up to 10 units, on-grid or off-grid
Up to 10 inverters can run in parallel for on-grid and off-grid operation.
Multiple batteries can be connected in parallel as well.
- 10 inverters in parallel
- On-grid parallel operation
- Off-grid parallel operation

Existing PV
AC couple an existing solar system
AC coupling retrofits this hybrid inverter onto an existing solar system.
The existing PV stays in place, and this inverter adds battery storage.
- AC couple retrofit existing PV

Scheduling
Six charge and discharge periods
Battery charging and discharging can be set across 6 time periods.
Each period is a charge or discharge window for the battery.
- 6 time periods

Generator
Store energy from a diesel generator
The inverter can store energy from a diesel generator in the battery.
That stored energy is available for later use.
- Diesel generator energy stored

Outdoor and monitoring
IP65, with open communication
Ingress protection is IP65.
Communication interfaces are RS485, RS232 and CAN. The display is LCD and LED.
Monitoring is optional: GPRS, Wi-Fi, Bluetooth, 4G or LAN.
- IP65 ingress protection
- RS485 RS232, CAN
- LCD+LED display
- Optional GPRS / Wi-Fi / 4G / LAN
Technical data
| Parameter | SUN-5K-SG02HP3-EU-DM2 | SUN-6K-SG02HP3-EU-DM2 | SUN-8K-SG02HP3-EU-DM2 | SUN-10K-SG02HP3-EU-DM2 | SUN-12K-SG02HP3-EU-DM2 |
|---|---|---|---|---|---|
| Rated AC active power | 5000 W | 6000 W | 8000 W | 10000 W | 12000 W |
| Max. AC apparent power | 5500 VA | 6600 VA | 8800 VA | 11000 VA | 13200 VA |
| Rated AC current | 7.6/7.3 A | 9.1/8.7 A | 12.2/11.6 A | 15.2/14.5 A | 18.2/17.4 A |
| Max. AC current | 8.4/8.0 A | 10/9.6 A | 13.4/12.8 A | 16.7/16 A | 20/19.2 A |
| Max. continuous AC passthrough | 35 A | 35 A | 35 A | 35 A | 35 A |
| Peak power (off-grid) | 1.5× rated, 10 s | 1.5× rated, 10 s | 1.5× rated, 10 s | 1.5× rated, 10 s | 1.5× rated, 10 s |
| Power factor | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging |
| THDi | <3% | <3% | <3% | <3% | <3% |
| DC injection current | <0.5% In | <0.5% In | <0.5% In | <0.5% In | <0.5% In |
| Rated voltage | 220/380 V, 230/400 V | 220/380 V, 230/400 V | 220/380 V, 230/400 V | 220/380 V, 230/400 V | 220/380 V, 230/400 V |
| Voltage range / phases | 0.85Un–1.1Un, 3L+N+PE | 0.85Un–1.1Un, 3L+N+PE | 0.85Un–1.1Un, 3L+N+PE | 0.85Un–1.1Un, 3L+N+PE | 0.85Un–1.1Un, 3L+N+PE |
| Grid frequency | 50/45–55, 60/55–65 Hz | 50/45–55, 60/55–65 Hz | 50/45–55, 60/55–65 Hz | 50/45–55, 60/55–65 Hz | 50/45–55, 60/55–65 Hz |
| Unbalanced output | 100% | 100% | 100% | 100% | 100% |
| Battery type | Lithium-ion | Lithium-ion | Lithium-ion | Lithium-ion | Lithium-ion |
| Battery voltage | 130–700 V | 130–700 V | 130–700 V | 130–700 V | 130–700 V |
| Max. charge/discharge current | 37 A | 37 A | 55 A | 55 A | 55 A |
| Li-ion charging strategy | Self-adaption to BMS | Self-adaption to BMS | Self-adaption to BMS | Self-adaption to BMS | Self-adaption to BMS |
| Battery inputs | 1 | 1 | 1 | 1 | 1 |
| Max. PV access power | 10000 W | 12000 W | 16000 W | 20000 W | 24000 W |
| Max. PV input power | 8000 W | 9600 W | 12800 W | 16000 W | 19200 W |
| Max. PV input voltage | 1000 V | 1000 V | 1000 V | 1000 V | 1000 V |
| Start-up voltage | 130 V | 130 V | 130 V | 130 V | 130 V |
| MPPT voltage range | 150–850 V | 150–850 V | 150–850 V | 150–850 V | 150–850 V |
| Rated PV input voltage | 600 V | 600 V | 600 V | 600 V | 600 V |
| Max. operating PV input current | 20+20 A | 20+20 A | 20+20 A | 20+20 A | 20+20 A |
| Max. input short-circuit current | 30+30 A | 30+30 A | 30+30 A | 30+30 A | 30+30 A |
| MPP trackers / strings | 2/1+1 | 2/1+1 | 2/1+1 | 2/1+1 | 2/1+1 |
| Max. efficiency | 97.6% | 97.6% | 97.6% | 97.6% | 97.6% |
| Euro efficiency | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% |
| MPPT efficiency | >99% | >99% | >99% | >99% | >99% |
| Parallel | Max. 10, on-grid and off-grid | Max. 10, on-grid and off-grid | Max. 10, on-grid and off-grid | Max. 10, on-grid and off-grid | Max. 10, on-grid and off-grid |
| Charge/discharge periods | 6 | 6 | 6 | 6 | 6 |
| AC coupling | Retrofit existing solar system | Retrofit existing solar system | Retrofit existing solar system | Retrofit existing solar system | Retrofit existing solar system |
| Diesel generator | Store generator energy | Store generator energy | Store generator energy | Store generator energy | Store generator energy |
| Ingress protection | IP65 | IP65 | IP65 | IP65 | IP65 |
| Surge protection | Type II (DC), Type II (AC) | Type II (DC), Type II (AC) | Type II (DC), Type II (AC) | Type II (DC), Type II (AC) | Type II (DC), Type II (AC) |
| Cooling | Natural cooling | Natural cooling | Intelligent air cooling | Intelligent air cooling | Intelligent air cooling |
| Operating temperature | −40 to +60°C, derating above 45°C | −40 to +60°C, derating above 45°C | −40 to +60°C, derating above 45°C | −40 to +60°C, derating above 45°C | −40 to +60°C, derating above 45°C |
| Ambient humidity | 0–100% | 0–100% | 0–100% | 0–100% | 0–100% |
| Altitude | 2000 m | 2000 m | 2000 m | 2000 m | 2000 m |
| Noise | ≤45 dB | ≤45 dB | ≤45 dB | ≤45 dB | ≤45 dB |
| Topology | Non-isolated | Non-isolated | Non-isolated | Non-isolated | Non-isolated |
| Overvoltage category | OVC II (DC), OVC III (AC) | OVC II (DC), OVC III (AC) | OVC II (DC), OVC III (AC) | OVC II (DC), OVC III (AC) | OVC II (DC), OVC III (AC) |
| Display | LCD+LED | LCD+LED | LCD+LED | LCD+LED | LCD+LED |
| Communication | RS485, RS232, CAN | RS485, RS232, CAN | RS485, RS232, CAN | RS485, RS232, CAN | RS485, RS232, CAN |
| Monitor mode | GPRS/Wi-Fi/Bluetooth/4G/LAN, optional | GPRS/Wi-Fi/Bluetooth/4G/LAN, optional | GPRS/Wi-Fi/Bluetooth/4G/LAN, optional | GPRS/Wi-Fi/Bluetooth/4G/LAN, optional | GPRS/Wi-Fi/Bluetooth/4G/LAN, optional |
| Warranty | 5 years / up to 10 years | 5 years / up to 10 years | 5 years / up to 10 years | 5 years / up to 10 years | 5 years / up to 10 years |